Alternator Brand and Model Mecc Alte - ECP 34-1L/4 C
Control Panel Model DSE 6120
Cabinet GTS 10
Product Features
Engine Specifications
Alternator Features
Control Panel Features
Cabin Features
Dimensions and Weights
Tab 1
Producer
Perkins
Engine Model
1106A-70TAG2
Cylinder and Design
6 cylinders - in line
Bore and Stroke (mm)
105 X 135
Total Cylinder Volume (L)
7.01
Compression Ratio
18.2:1
Engine Speed (rpm)
1500
Standby Power (kW/hp)
149.1/199.86
Prime Power(kW/hp)
136/182.3
Block Heater (Adt)
1
Block Heater Power (Watt)
1500
Governor System
Mechanic
Air Filter<br>
Dry Type
Air intake
Turbo Charged and Charge Air Cooled
Oil Capacity (L)
18
Max. Oil Temperature ⁰C (F)
125
Fuel Type
Diesel
Injection Type
Direct
Fuel Pump Type
Delphi DP210G Rotary Type
Operating Voltage (Vdc)
12 Vdc
Battery and Capacity (Unit/Ah)
1x85
Cooling Method
Water Cooled
Coolant Capacity (engine only)l (gal)
9.5
Exhaust Gas Flow (m³/min)
25.53
Exhaust Back Pressure in-Hg (kPa)
6
Exhaust Gas Temperature ⁰C (F)
484
Total Cooling Water Capacity (l)
21
Fuel Consumption at 50% Prime Load l/h (kg/h)
16.4
Fuel Consumption at 75% Prime Load l/h (kg/h)
24.7
Fuel Consumption at 100% Prime Load l/h (kg/h)
33.4
Tab 2
Producer
Mecc Alte
Alternatrr Model
ECP 34-1L/4 C
Frequency (Hz)
50
Power (kVA)
150
Voltage (V)
400
Phalse
3
A.V.R.
DSR
Voltage Regulation
1
Insulation Class
H
Protection Class
IP23
Nominal Power Factor
0.8
Total Generator Weight (kg)
423
Cooling Air (m³/min)
29.2
Tab 3
Generator and Control Module Model
DSE 6120
1. Menu navigation buttons 2. Close mains button 3. Main Status and instrumentation display 4. Alarm LED's 5. Close generator button 6. Status LED's 7. Operation selecting buttons
Standard Devices
DSE model 6120, Auto Mains Failure control module, Static battery charger input 198-264 volt, output 27,6V 5A (24V) or
13,8 Volt 5A (12V), fuses for control circuits. This Control Module is suitable for a wide variety of single gen-set applications
Control Unit
- The DSE 6120 module has been designed to monitor generator frequency, volt, current, engine oil pressure, coolant
temperature running hours and battery volts.
- Module monitors the mains supply and control the switch over to the generator when the mains power fails.
- The DSE6120 also indicates operational status and fault conditions, Automatically shutting down the Gen. Set and giving
true first up fault condition of Gen. Set failure.The LCD display indicates the fault.
Construction and Painting
Components installed in sheet steel enclosure. Phosphate chemical, pre-coating of steel provides corrosion corrosion-resistant surface. Polyester composite powder topcoat forms a high gloss and extremely durable finish. Lockable and hinged panel door provides easy access to components.
Assembly
Control panel is mounted on baseframe with steel stand. Located at the right side of the generator set (When you look at the Gen.Set. from Alternator side)
- Engine speed
- Oil pressure
- Coolant temperature
- Run time
- battery volts
- Configurable timing
- Fail to start
- Emergency stop
- Low oil pressure
- High coolant temperature
- Over /Under speed
- Under/over generator frequency
- Under/over generator voltage
- Oil pressure sensor open
- Coolant temperature sensor open
- Charge failure
- Battery Low/High voltage
- Fail to stop.
- Low /High generator voltage
- Under /Over generator frequency
- Over /Under speed
- Low oil pressure
- High coolant temperature
- Voltage (L-L, L-N)
- Current (L1-L2-L3)
- Frequency
- Gen. Set ready
- Gen. Set enabled
- Generator over current
- Mains ready
- Mains enabled
Options
- Flexible sensor can be controlled with temperature, pressure, percentage (warning/shutdown/electrical trip)
- Local setting parameters and monitoring from PC to control module with USB connection (max 6 mt).