Alternator Brand and Model Mecc Alte - ECO 46-1L/4 A
Control Panel Model DSE 7320
Cabinet AK 99 - External Removable Silencer
Product Features
Engine Specifications
Alternator Features
Control Panel Features
Cabin Features
Dimensions and Weights
Tab 1
Producer
Mitsubishi
Engine Model
S16R-PTAA2
Cylinder and Design
16 cylinders - V type
Bore and Stroke (mm)
170 X 180
Total Cylinder Volume (L)
65.37
Compression Ratio
14.0:1
Engine Speed (rpm)
1500
Standby Power (kW/hp)
1939/2599
Prime Power(kW/hp)
1728/2316
Block Heater (Adt)
2
Block Heater Power (Watt)
3000
Governor System
Electronic
Air Filter<br>
Dry Type
Air intake
Turbo Charged and After Cooled
Oil Capacity (L)
230
Max. Oil Temperature ⁰C (F)
110
Fuel Type
Diesel
Injection Type
Direct
Fuel Pump Type
Mitsubishi PS8x2 (In-Line)
Operating Voltage (Vdc)
UNKNOWN
Battery and Capacity (Unit/Ah)
4x143
Cooling Method
Water Cooled
Coolant Capacity (engine only)l (gal)
170
Total Cooling Water Capacity (l)
413
Cooling Fan Air Flow m³/min (ft³/min)
2500
Fuel Consumption at 50% Prime Load l/h (kg/h)
216.8
Fuel Consumption at 75% Prime Load l/h (kg/h)
313.1
Fuel Consumption at 100% Prime Load l/h (kg/h)
403.8
Tab 2
Producer
Mecc Alte
Alternatrr Model
ECO 46-1L/4 A
Frequency (Hz)
50
Power (kVA)
2100
Voltage (V)
400
Phalse
3
A.V.R.
DER1
Voltage Regulation
0.5
Insulation Class
H
Protection Class
IP23
Nominal Power Factor
0.8
Total Generator Weight (kg)
3810
Cooling Air (m³/min)
135
Tab 3
Generator and Control Module Model
DSE 7320
1. Menu navigation buttons 2. Close mains button 3. Main Status and instrumentation display 4. Alarm LED's 5. Close generator button 6. Status LED's 7. Operation selecting buttons
Standard Devices
DSE model 7320, Auto Mains Failure control module, with a highly sophisticated level of new features and functions
Static battery charger, Fuses for control circuits
Control Unit
- The DSE 7320 control module is a standard addition to our generator sets from 220 kVA upwards and it has been
designed to start and stop diesel and gas generating sets that include electronic and non electronic engines.
- The DSE 7320 includes the additional capability of being able to monitor a mains (utility) supply and is therefore suitable
for controlling a standby generating set in conjunction with an automatic transfer switch.
- The DSE7320 also indicates operational status and fault conditions, automatically shutting down the generating set and
indicating faults by means of its LCD display on the front panel.
Construction and Painting
- Components installed in sheet steel enclosure.
- Phosphate chemical, pre-coating of steel provides corrosion resistant surface
- Polyester composite powder topcoat forms high gloss and extremely durable finish
- Lockable hinged panel door provides for easy component access
Assembly
The Control panel is mounted at the generating set baseframe on robust steel stand or power module. Located at side
of generating set with properly panel visibility.
-Enginespeed
-Oilpressure
-Coolanttemperature
-Runtime
-Batteryvolts
-Enginemaintenancedue
-Failtostart
-Emergencystop
-Lowoilpressure
-Highenginetemperature
-Lowcoolantlevel
-Under/overspeed
-Under/overgeneratorfrequency
-Under/overgeneratorvoltage
-Oilpressuresensoropen
-Phaserotation
-Chargefailure
-Batteryundervoltage
-Failtostop
-Lowfuellevel(opt.)
-kWoverload
-Negativephasesequence
-Lossofspeedsignal
-Voltage(L-L,L-N)
-Current(L1-L2-L3)
-Frequency
-Earthcurrent
-kW
-Pf
-kVAr
-kWh,kVAh,kVArh
-Phasesequence
-Earthfault
-kWoverload
-Generatorovercurrent
-Negativephasesequence
-Voltage(L-L,L-N)
-Frequency
Options
- High oil temperature shut down
- Low fuel level shut down
- Low fuel level alarm
- High fuel level alarm
Options Control Panel Compatibility List
- Electrical Safety / Electro Magnetic Compatibility (EMC)
- BS EN 61000-6-2 EMC Generic Immunity Standard
- BS EN 61000-6-4 EMC Generic Emission Standard
- BS EN 60950 Electrical Safety
Static Battery Charger
- Battery charger is manufactured with switching-mode and SMD technology and it has high efficiency.
- Battery charger models' output V-I characteristic is very close to square
- 2405 has fully output shot circuit protection and it can be used as a current source.
- 2405 charger has high efficiency, long life, low failure rate, light-weight and low heat radiated in accordance
with linear alternatives.
- The charger is fitted with a protection diode across the output.
- Charge fail output is available.
- Connect charge fail relay coil between positive output and CF output.
- Input: 196-264V.
- Output: 27,6V 5A or 13,8V 5A.
Tab 4
Canopy
AK 99 - External Removable Silencer
1. Steel structure made from steel sheet and steel profiles. 2. Canopy and panels made from powder coated sheet steel. 3. Emergency stop push button. 4. Control panel is mounted on the baseframe located at the back of the Generator set. 5. Cables out locations are at the back of the canopy. 6. Corrosion-resistant locks and hinges. 7. Oil could be drained via valve and a hose. 8. Exhaust system on the canopy. 9. Special large access doors for easy maintenance. 10. The cap on the canopy provides easy access to the radiator cap. 11. Lifting points similar to ISO container, located on each top corner of the Canopy. 12. Soundproofing materials. 13. Fuel tank is in front of the canopy, easy access to the fuel tank via lockable door. 14. Integrated ladder built on the side of the canopy allows access to the top of the canopy.
Introductıon
Sound-attenuated and weather-protective enclosures for generating sets from Aksa, meet event the sound requirements and provide optimum protection from inclement weather and development by our specialist acoustic engineers. Our modular designed sound insulated canopies provide ease of access for servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed to optimize genset cooling performance, providing you with confidence that genset ratings and ambient capability.
General Characteristics
Compact footprint, low profile design.
Enclosure, generator set, exhaust system and fuel tank are pre-assembled, pre-integrated, and shipped as one package
Body made from steel components treated with polyester powder coating
Fire retardant foam insulation
Easy access to all service points
Exhaust system inside the canopy
Large doors on each side
Control panel viewing window in a lockable access door
Emergency stop push button mounted on enclosure exterior
Cooling fan and battery charging alternator are fully guarded
Fuel fill and battery can only be reached via lockable access doors.
Lifting points on the top of the canopy and base frame
Customer options available to meet your application's needs.
Aksa makes its generating sets' noise level tests in accordance with directive 2000/14/EC validation of the noise level test has been approved by the notified body Szutest
Length (mm)
9000
Width (mm)
2800
Height (mm)
3307
Fuel Tank Capacity (l)
2200
Tab 5
Open Group
Cabin Group
Tab 1
*Images are for illustrative purposes only; actual presentation may vary.