ACG 1540

ACG 1540

Fuel Type -
3Phalse
50hz

General Features

  • Model Name ACG 1540

  • Frequency (Hz) 50

  • Engine Brand and Model -

  • Alternator Brand and Model Mecc Alte - ECO46 1,5L/4A

  • Control Panel Model AGC-4 Mk II

  • Cabinet

Product Features

  • altEngine Specifications
  • altAlternator Features
  • altControl Panel Features
  • altCabin Features
  • altDimensions and Weights

Tab 1

  • Producer

  • Engine Model

  • Cylinder and Design

  • Bore and Stroke (mm)

  • X

  • Total Cylinder Volume (L)

  • Compression Ratio

  • Engine Speed (rpm)

  • Standby Power (kW/hp)

  • Prime Power(kW/hp)

  • Block Heater (Adt)

  • Block Heater Power (Watt)

  • Governor System

  • Air Filter<br>

  • Air intake

  • Oil Capacity (L)

  • Max. Oil Temperature ⁰C (F)

  • Fuel Type

  • Injection Type

  • Fuel Pump Type

  • Operating Voltage (Vdc)

  • Battery and Capacity (Unit/Ah)

  • Cooling Method

  • Coolant Capacity (engine only)l (gal)

  • Exhaust Gas Flow (m³/min)

  • Exhaust Back Pressure in-Hg (kPa)

  • Exhaust Gas Temperature ⁰C (F)

  • Total Cooling Water Capacity (l)

  • Cooling Fan Air Flow m³/min (ft³/min)

  • Fuel Consumption at 50% Prime Load l/h (kg/h)

  • Fuel Consumption at 75% Prime Load l/h (kg/h)

  • Fuel Consumption at 100% Prime Load l/h (kg/h)

Tab 2

  • Producer

  • Mecc Alte

  • Alternatrr Model

  • ECO46 1,5L/4A

  • Frequency (Hz)

  • 50

  • Power (kVA)

  • 2050

  • Voltage (V)

  • 400

  • Phalse

  • 3

  • A.V.R.

  • DER1

  • Voltage Regulation

  • ±0.5

  • Insulation Class

  • H

  • Protection Class

  • IP23

  • Nominal Power Factor

  • 1

  • Total Generator Weight (kg)

  • 4260

  • Cooling Air (m³/min)

  • 135

Tab 3

  • Generator and Control Module Model

  • AGC-4 Mk II

  • - Terminal 1-28, power supply
    - Terminal 29-36, communication
    - Terminal 37-64, in-/outputs/load sharing
    - Terminal 65-72, governor, AVR, in-/outputs
    - Terminal 73-89, AC measuring
    - Terminal 90-97, in-/outputs
    - Terminal 98-125, engine I/F
    - Terminal 126-133, engine communication, in-/outputs
    - LED I/F and Ethernet
  • Standard Devices

  • ● Additional CAN bus based I/O (9 x CIO modules)
    ● Redundant controller
    ● Redundant CAN bus for Power mamangement
    ● N+X configuration
    ● Close Before Excitation / Run-up synchronization from 6 seconds
    ● DEIF digital AVR DVC550 support
    ● Multi purpose PIDs
  • Control Unit

  • The AGC-4 Mk II is a configurable controller that can be used in applications ranging from a single controller for one genset, to
    complete power management systems. The controller contains the 3-phase measuring circuits and all the functions required to
    protect and control a genset. The controllers can also be used to protect and control mains connections, tie breakers, and bus tie
    breakers.
  • Construction and Painting

  • Controller: IP20. DU-2 display and AOP: IP40 (IP54 with gasket: Option L).
    UL/cUL Listed: Type Complete Device, Open Type. To EN/IEC 60529
  • Assembly

  • The controller is designed for mounting inside the panel. The DU-2 display can be installed on the panel door and connected to the
    controller with a display cable.
  • ● Automatic Mains Failure sequence
    ● Multi-master Power Management
    ● Power Management Core (32dg)
    ● Power Management Extended (>32dg)
    ● RMB Transformer maintenance with up to 32 gensets
    ● PLC logic
    ● Engine CAN bus
    ● DIN rail mount
    ● Flexible Hardware
  • Options

  • ● Terminal 1-28, power supply
    ● 8 to 36 V DC supply, 11 W; 1 x status output relay; 5 x relay outputs; 2 x pulse outputs (kWh, kvarh or  configurable open collector outputs); 5 x digital inputs
    ● Terminal 29-36, communication
    ● Modbus RTU (RS-485)
    ● Profibus DP
  • Options Control Panel Compatibility List

  • ● EN/IEC 61010-1, installation category (over-voltage category) III, 600 V, pollution degree 2
    ● EN/IEC 60255-27 over-voltage category III, 600 V, pollution degree 2
    ● UL/ULC 6200:2019 1.ed, over-voltage category III, 600 V, pollution degree 2
    ● Gridcode compliant with: VDE AR-N 4110/4105 (Medium voltage, Germany, VDE AR-N 4105 (low voltage, Germany, EN 50549-1:2019 (Europe), ENA EREC G99 (United Kingdom)
    ● TÜV and UL approved
    ● Tier4 final/stageV
  • Static Battery Charger

  • Battery charger is manufactured with switching-mode and SMD technology and it has high efficiency.
    Battery charger models' output V-I characteristic is very close to square
    2405 has fully output short circuit protection and ıt can be used as a current source.
    2405 charger has high efficiency, long life, low failure rate, lightweight and low heat radiated in accordance with linear alternatives.
    The charger is fitted with a protection diode across the output.
    Charge fail output is available.
    Connect charge fail relay coil between the positive output and CF output.
    Input: 196-264V.
    Output: 27,6V 5A or 13,8V 5A.

Tab 4

  • Canopy

  • Introductıon

  • General Characteristics

  • Length (mm)

  • Width (mm)

  • Height (mm)

  • Fuel Tank Capacity (l)

Tab 5

Tab 1

alt

*Images are for illustrative purposes only; actual presentation may vary.

    • Open Group
    • Length (mm)(A)
    • Width (mm)(B)
    • Height (mm)(C)
    • Gross Weight Dry (kg.)
    • Full Tank Capacity (lt.)
    • 5180 (17)
    • 2099 (6,9)
    • 2972 (9,5)
    • -
    • -

Tab 2

alt

*Görseller temsilidir, sunumları farklılık gösterebilir.

    • Canopy Group
    • Length (mm)(A)
    • Width (mm)(B)
    • Height (mm)(C)
    • Gross Weight Dry (kg.)
    • Full Tank Capacity (lt.)
    • canopy
    • canopy
    • canopy
    • canopy
    • -
    • fueL_TANK_DETAILS_DRWGS

Optional Equipment

Certificates

(Türkçe)

(English)

(French)

(Spanish)

(Russian)