APD-T 55 BD-S3A

Aksa power generation system, providing optimum performance, and reliability, for stationary prime power exclusively for Telecommunication.. All generator sets are factory build, and production tested.
Model Name |
APD-T 55 BD-S3A |
||
---|---|---|---|
Frequency (Hz) |
50 |
||
Fuel Type |
Diesel |
||
Engine Made and Model |
Baudouin - 4M10G2D3/5 |
||
Alternator Made and Model |
Aksa - AK 351 |
||
Control Panel Model |
D-500 |
||
Canopy | AKCELL-30 |
VOLTAGE | STANDBY RATING (ESP) | PRIME RATING (PRP) | Standby Amper | ||
---|---|---|---|---|---|
kVA | kW | kVA | kW | ||
400/231 | 55 | 44.00 | 50 | 40.00 | 79.39 |
PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation.
Engine |
Baudouin |
||
---|---|---|---|
Engine Model | 4M10G2D3/5 | ||
NO. OF CYLINDERS AND BUILD | 4 cylinders - in line | ||
BORE AND STROKE | mm | 105 X 118 | |
TOTAL DISPLACEMENT | L | 4.09 | |
Aspiration | Turbo Charged and After Cooled | ||
COMPRESSION RATIO | 17.5:1 | ||
RATED SPEED (RPM) | d/dk | 1500 | |
OIL CAPACITY | L | 13 | |
Standby Power (kW/HP) | 66/89 | ||
Prime Power | 60/81 | ||
Block Heater QTY | |||
1 | |||
Block Heater Power (Watt) | |||
750 | |||
Fuel Type | |||
Diesel | |||
Injection Type and System | |||
Direct | |||
Type of Fuel Pump | |||
HPCR (High Pressure Common Rail) | |||
Governor System | |||
ECU | |||
Operating Voltage (Vdc) | |||
12 Vdc | |||
Battery and Capacity (Qty/Ah) | |||
1x66 | |||
Charge Alternator (A) | |||
80 | |||
Cooling Method | |||
Water Cooled | |||
Cooling Fan Air Flow (m3/min) | |||
125.7 | |||
Coolant Capacity (engine only) (l) | |||
9.4 | |||
Total Coolant Capacity (l) | |||
36 | |||
Air Filter | |||
Dry Type | |||
Fuel Cons. Prime With %100 Load (lt/hr) | |||
14.21 | |||
Fuel Cons. Prime With %75 Load (lt/hr) | |||
10.96 | |||
Fuel Cons. Prime With %50 Load (lt/hr) | |||
7.71 |
Manufacturer | Aksa | |
---|---|---|
Alternator Made and Model | AK 351 | |
Frequency (Hz) | Hz | 50 |
Power (kVA) | kVA | 64 |
DESIGN | Brushless | |
VOLTAGE | V | 400 |
Phase | 3 | |
A.V.R. | SX460 | |
Voltage Regulation | (+/-) | 1 |
Insulation System | H | |
Protection | IP22 | |
Rated Power Factor | 0.8 | |
WEIGHT COMP. GENERATOR (Kg) | 311 | |
COOLING AIR (m³/min) | m3 | 12,96 |
Open Type | DRY WEIGHT (kg.) (kg.) |
LENGTH (mm.) |
WIDTH (mm.) |
HEIGHT (mm.) |
TANK CAPACITY (lt.) (Lt.) |
---|---|---|---|---|---|
CANOPY | DRY WEIGHT (kg.) (kg.) |
LENGTH (mm.) |
WIDTH (mm.) |
HEIGHT (mm.) |
TANK CAPACITY (lt.) (Lt.) |
AKCELL-30![]() |
2600 | 1272 | 1608 |
- Ambient heater
- Resizable fuel tank
- Automatic or manual fuel filling system
- Electrical or manual oil drain pump
- Low and high fuel level alarm
- Inlet and outlet motorized louvers
- Inlet and outlet acoustic baffles
- Tool kit for maintenance
- 1500/3000 hours maintenance kit
- Supplied with oil and coolant (-30°C)

Close mains button
Main Status and instrumentation display
Alarm LED's
Close generator button
Status LED's
Operation selecting buttons
Maximum humidity: 95% non-condensing.
IP Protection: IP65 from front panel, IP30 from the rear (with gasket)
Dimensions: 200 x 148 x 46mm (WxHxD)
Panel Cut-out Dimensions: 176 x 121 mm minimum.
Weight: 450 g (approx.)
Case Material: High Temperature, non-flammable ABS/PC
• Battery charge run enabled
• Battery voltage
STANDARD SPECIFICATIONS
• Fuel filling & fuel theft alarms
• Idle speed control
• Combat mode support
• Multiple nominal conditions
• Contactor & MCB drive
• 4 quadrant genset power
counters
• Mains power counters
• Fuel filling counter
• Fuel consumption counter
• Modem & ethernet diagnostics
• Configurable through USB,
RS-485, Ethernet and GPRS
• Free configuration program
• Allows SMS controls
• Ready for central monitoring
Ethernet & GPRS
• Mobile genset support
• Automatic GSM geo-location
• GPS connectivity (USB&RS232)
• Mains & genset PN/PP voltages
• Mains & genset frequency
• Mains & genset phase currents
• Mains & genset neutral currents
• Mains & genset, phase & total,
kW, kVA, kVAr, pf
• Engine speed
• Disable protections feature
• Excess power protection
• Reverse power protection
• Overload IDMT protection
• Load shedding, dummy load
• Multiple load management
• Current unbalance protection
• Voltage unbalance protection
• 4-band GPRS modem (optional)
EU Directives Conformity
-2006/95/EC (low voltage)
-2004/108/EC (electro-magnetic compatibility)
Norms of reference:
EN 61010 (safety requirements)
EN 61326 (EMC requirements)
UL & CSA Compatibility:
• UL 6200, Controls for Stationary Engine Driven
Assemblies (File# - 20140725-E314374)
• CAN/CSA C22.2 No. 14-13 – Industrial Control
Equipment
Battery charger models' output V-I characteristic is very close to square
2405 has fully output short circuit protection and ıt can be used as a current source.
2405 charger has high efficiency, long life, low failure rate, lightweight and low heat radiated in accordance with linear alternatives.
The charger is fitted with a protection diode across the output.
Charge fail output is available.
Connect charge fail relay coil between the positive output and CF output.
Input: 196-264V.
Output: 27,6V 5A or 13,8V 5A.
CANOPY MODEL | AKCELL-30 | |
---|---|---|
WIDTH | mm. | 1272 |
LENGTH | mm. | 2600 |
HEIGHT | mm. | 1608 |
TANK CAPACITY (lt.) | Lt. |