APD 2100 M

APD 2100 M

Fuel Type Diesel
3Phalse
50hz
    • 230/400V
    • kVA

    • kW

    • Power Prime

    • 1875

    • 1500.0

    • Power Standby

    • 2100

    • 1680.0

General Features

  • Model Name APD 2100 M

  • Frequency (Hz) 50

  • Fuel Type Used Diesel

  • Engine Brand and Model -

  • Alternator Brand and Model Mecc Alte - ECO 46-1L/4 A

  • Control Panel Model DSE 7320

  • Cabinet AK 99

Product Features

  • altEngine Specifications
  • altAlternator Features
  • altControl Panel Features
  • altCabin Features
  • altDimensions and Weights

Tab 1

  • Producer

  • Engine Model

  • Cylinder and Design

  • Bore and Stroke (mm)

  • X

  • Total Cylinder Volume (L)

  • Compression Ratio

  • Engine Speed (rpm)

  • Standby Power (kW/hp)

  • Prime Power(kW/hp)

  • Block Heater (Adt)

  • Block Heater Power (Watt)

  • Governor System

  • Air Filter<br>

  • Air intake

  • Oil Capacity (L)

  • Max. Oil Temperature ⁰C (F)

  • Fuel Type

  • Injection Type

  • Fuel Pump Type

  • Operating Voltage (Vdc)

  • Battery and Capacity (Unit/Ah)

  • Cooling Method

  • Coolant Capacity (engine only)l (gal)

  • Exhaust Gas Flow (m³/min)

  • Exhaust Back Pressure in-Hg (kPa)

  • Exhaust Gas Temperature ⁰C (F)

  • Total Cooling Water Capacity (l)

  • Cooling Fan Air Flow m³/min (ft³/min)

  • Fuel Consumption at 50% Prime Load l/h (kg/h)

  • Fuel Consumption at 75% Prime Load l/h (kg/h)

  • Fuel Consumption at 100% Prime Load l/h (kg/h)

Tab 2

  • Producer

  • Mecc Alte

  • Alternatrr Model

  • ECO 46-1L/4 A

  • Frequency (Hz)

  • 50

  • Power (kVA)

  • 2100

  • Voltage (V)

  • 400

  • Phalse

  • 3

  • A.V.R.

  • DER1

  • Voltage Regulation

  • 0.5

  • Insulation Class

  • H

  • Protection Class

  • IP23

  • Nominal Power Factor

  • 0.8

  • Total Generator Weight (kg)

  • 3810

  • Cooling Air (m³/min)

  • 135

Tab 3

  • Generator and Control Module Model

  • DSE 7320

  • Standard Devices

  • Control Unit

  • Construction and Painting

  • Assembly

  • Options

  • Options Control Panel Compatibility List

  • Static Battery Charger

Tab 4

  • Canopy

  • AK 99

  • 1- Steel structure made from steel sheet and steel profiles.
    2- Canopy and panels made from powder coated sheet steel.
    3- Emergency stop push button.
    4- Control panel is mounted on the baseframe . Located at the back
    of Generator set 
    5- Cables out locations are back of the canopy.
    6- Corrosion-resistant locks and hinges.
    7- Oil could be drained via valve and a hose 
    8- Exhaust system on the canopy.
    9- Special large access doors for easy maintanance
    10- The cap on the canopy provides easy accsess to radiator cap.
    11- Lifting points similar to ISO container , located on each top corner of the
    Canopy.
    12- Sound proofing materials
    13- Ventilation louvres
    14- Integrated ladder built in to side of the canopy allows access to the top of the canopy

  • Introductıon

  • Sound-attenuated and weather-protective enclosures for generating sets from Aksa, meet event the sound requirements and provide optimum protection from inclement weather and development by our specialist acoustic engineers. Our modular designed sound insulated canopies provide ease of access for servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed to optimize genset cooling performance, providing you with confidence that genset ratings and ambient capability.

  • General Characteristics

  • Compact footprint, low profile design. 
    Enclosure, generator set, exhaust system and fuel tank are pre-assembled, pre-integrated and shipped as one package 
    Body made from steel components treated with polyester powder coating 
    Fire retardant foam insulation 
    Easy access to all service points 
    Exhaust system inside canopy 
    Large doors on each side 
    Control panel viewing window in a lockable access door 
    Emergency stop push button mounted on enclosure exterior 
    Cooling fan and battery charging alternator fully guarded 
    Fuel fill and battery can only be reached via lockable access doors. 
    Lifting points on the top of canopy and base frame 
    Customer options available to meet your application's needs. 
    Aksa makes its generating sets' noise level tests in accordance with directive 2000/14/EC validation of the noise level test has been approved by the notified body Szutest

  • Length (mm)

  • 9000

  • Width (mm)

  • 2800

  • Height (mm)

  • 3457

  • Fuel Tank Capacity (l)

  • 2200

Tab 5

Tab 1

alt

*Images are for illustrative purposes only; actual presentation may vary.

    • Open Group
    • Length (mm)(A)
    • Width (mm)(B)
    • Height (mm)(C)
    • Gross Weight Dry (kg.)
    • Full Tank Capacity (lt.)
    • 5223
    • 2245
    • 2608
    • 13100
    • 2000

Tab 2

alt

*Görseller temsilidir, sunumları farklılık gösterebilir.

    • Canopy Group
    • Length (mm)(A)
    • Width (mm)(B)
    • Height (mm)(C)
    • Gross Weight Dry (kg.)
    • Full Tank Capacity (lt.)
    • AK 99
    • 9000
    • 2800
    • 3457
    • 18350
    • fueL_TANK_DETAILS_DRWGS

Optional Equipment

  • altEngine
  • altAlternator
  • altCabin
  • altControl Panel
  • altTransfer Board
  • altAuxiliary Equipment
  • altExhaust
  • altCabin Optionall

Engine

- Fuel-Water Seperator Filter

- Oil heater

Alternator Characteristics

- Anti-Condensation Heater

- Over sized alternator

- PMG excitation + AVR

- Main line circuit breaker

Canopy Characteristics

- Galvanized Coating

- ISO Container

- Marine Grade Paint

Control Panel

- Automatic synchronising and power control system (Multi gen-set Parallel)

- Parallel system with mains

- Transition synchronization with mains

- Alarm output relays

- Earth fault, single set

- Parallel system with mains

- Remote relay output

- Remote communication with modem

- Charge Ammeter

Transfer Panel

- Three or four pole contactor

- Three or four pole motor operated circuit breaker

Auxiliary Equipment

- Main Fuel Tank

- Automatic or manual fuel filling system

- Electrical or manual oil drain pump

- Low and high fuel level alarm

- Inlet and outlet motorized louvers

- Inlet and outlet acoustic baffles

- Tool kit for maintenance

- 1500/3000 hours maintenance kit

- Supplied with oil and coolant (-30°C)

Exhaust

- Residential Silencer

- Silencer Spark Arrester

- Critical Silencer

- Catalytic Convertor

Canopy Optional Alternator and Control Panel

Please contact to your reseller for additional Alternator, Control Panel and Breaker Switch options.

Certificates

Directive

- 2006/42/EC : Machinery Safety Directive

- 2014/30/EU : Electromagnetic Compatibility Directive

- 2014/35/EU : Low Voltage Directive

Standarts

- TS ISO 8528-5:2022 / TS EN ISO 8528-13:2018 : Reciprocating internal combustion engine-driven alternating

current generating sets- Part:13: Safety


Quality Management Systems

ISO 9001:2015

ISO 14001:2015

ISO 45001:2018

ISO 50001:2018

ISO 27001:2013

ISO 10002:2018


(Türkçe)

(English)

(French)

(Spanish)

(Russian)

(Arabic)

(German)

(Chinese)